A heat pump that runs for hours on a very cold day is often doing exactly what it was designed to do: Carrier notes it can be completely normal for a unit to run all the time in extreme temperatures. Constant running in mild weather is different. Carrier points first to a dirty filter, a wrong thermostat setting or a dirty outdoor coil, and beyond those to a frozen coil, a reversing valve, low refrigerant or the compressor. A unit that keeps running with the thermostat off is a stuck electrical part and needs a technician.

First: what's the weather doing?

The same symptom means different things depending on the outdoor temperature.

Situation Usually means
Very cold out, heat pump runs for hours, house stays warm Normal. It's working hard to pull heat from cold air.
Very cold out, runs nonstop, house slowly falls behind, aux heat on a lot Heat pump at its limit, or a problem. See aux heat.
Mild weather, runs nonstop and never reaches the setpoint A problem. Work through the checks below.
Thermostat off, outdoor unit still running Electrical fault. See won't shut off at all.
Only the indoor fan runs all the time, air feels cool Usually the fan is set to On.

Why long runs in the cold are normal

A heat pump doesn't make heat; it moves heat from outdoor air into the house. The colder the air, the less heat there is to move and the harder the job. Carrier says it can be completely normal for a unit to run all the time in extreme temperatures. Lennox notes that standard heat pumps begin to struggle somewhere below roughly 25 to 30°F, which is why many systems have backup heat. Newer cold-climate models are built to keep going well below freezing.

A heat pump also delivers milder air than a furnace: Trane puts typical heat pump supply air at about 85 to 93°F, which can feel cool on your hand. So it tends to run longer to deliver the same heat. If the house is holding the temperature you set, long runs on a cold day aren't a fault.

In mild weather: the checks, in order

Carrier's own short list for a heat pump that runs constantly in moderate weather is a dirty air filter, an incorrect thermostat setting or a dirty outdoor coil. Start there.

1. The fan setting

If the thermostat fan is set to On rather than Auto, the indoor blower runs all the time, even when the heat pump isn't heating or cooling. Trane explains that on this setting you'll hear the blower and feel air from the vents, but the outdoor unit isn't running. Carrier adds that air circulated this way can feel room temperature or cool. Set the fan to Auto.

2. The thermostat mode and setpoint

  • Wrong mode. Carrier's first check: is it set to cooling in winter? Switch to Heat.
  • An unreachable setpoint. Lennox explains that a thermostat set far beyond what the system can reach keeps it running toward a temperature it never gets to. Set it a few degrees from the current room temperature and see whether it cycles off.
  • Big jumps. Lennox notes that raising the setpoint more than 3 or 4 degrees at once takes a heat pump a while to catch up and is a common reason aux heat kicks in. Small, steady settings work better than big setbacks and recoveries.
  • A failing thermostat. Trane says thermostat sensors collect dirt and wiring can loosen with age, interfering with the signal to the system. If the reading on the thermostat doesn't match a separate thermometer, the thermostat may be the problem.

3. The air filter

Carrier says a dirty or clogged filter makes the system run longer and less effectively. It's the cheapest fix on this list. Trane recommends changing it every 30 to 90 days.

4. The outdoor coil

A coil packed with dirt, leaves or cottonwood can't exchange heat well, and Carrier says an extremely dirty one may leave the system unable to keep up. In winter, look for snow drifted against the sides or ice that never clears. Clear 2 feet around the unit and see our heat pump maintenance guide for safe coil cleaning.

5. Ice and defrost

Frost on the outdoor coil is normal in cold, damp weather, and the defrost cycle melts it by reversing operation for a few minutes, as Lennox explains. Lennox adds that defrosting even at around 45°F isn't unusual. But if the unit seems to enter defrost too often or runs unusually long defrost cycles, or ice keeps building up, something isn't right. See heat pump blowing cold air for what defrost looks like and what to do about heavy ice.

6. Deeper problems (technician)

If it's mild outside, the system was recently serviced and it still runs constantly, Carrier lists the likely deeper causes: a frozen coil, a malfunctioning reversing valve, low refrigerant or a compressor problem. A system that's too small for the house also runs nonstop; Trane notes an undersized unit works overtime and wears out faster. Lennox adds that wiring damage and loose connections can make a system run longer than it should. All of these need a technician's diagnosis.

Aux heat that stays on

On cold days you'll see Aux (auxiliary heat) on many heat pump thermostats. That's backup heat, usually electric strips or a gas furnace, helping the heat pump. Lennox says the most common reason it engages is outdoor temperatures dropping below about 40°F, and that it also comes on during defrost.

Lennox's guideline: aux heat that comes on frequently, or stays on more than about 30 minutes at a time, means the heat pump can't handle the workload. Lennox suggests switching to emergency heat if you have it and calling a technician. It also notes that a failed defrost control board can make the system think it's in defrost far more often than needed, keeping aux heat on. Since backup heat is usually the expensive part, this is worth catching early.

It won't shut off even with the thermostat off

Set the thermostat to Off. If the outdoor unit keeps running, the thermostat is no longer in control. Trane explains that if the compressor contactor (a relay) welds closed, the unit keeps running with constant power. A thermostat wiring fault can do the same.

Turn the system off at the outdoor disconnect or its breaker, and call a technician. Trane notes this is an electrical issue for a professional. Running a compressor nonstop with no control isn't something to leave going.

In cooling season

A heat pump in summer is an air conditioner, and the same causes apply: fan on On, a setpoint far below room temperature, a dirty filter, a dirty coil, a frozen indoor coil or low refrigerant. Lennox says an air conditioner shouldn't run constantly; long runs raise energy costs and add wear. See AC not blowing cold air for the cooling checks.

When to call a pro

If the opposite is happening, a system that won't start at all, see heat pump not turning on. All topics: heat pump troubleshooting.

Questions people ask

Is it normal for a heat pump to run constantly in winter?

In very cold weather, yes. Carrier says a heat pump can run all the time in extreme temperatures as it works to pull enough heat from the outdoor air. Lennox notes standard heat pumps start to struggle below roughly 25 to 30°F. What isn't normal is nonstop running in mild weather, or a house that never reaches the setpoint even in moderate cold.

How long should a heat pump run per cycle?

There's no single number; it depends on outdoor temperature, house size and the equipment. In mild weather it should reach the setpoint and shut off. In deep cold, long cycles or near-continuous running are expected. The thing to watch is whether the house stays at the temperature you set.

Why is my aux heat always on?

Short bursts on cold days or after you raise the thermostat are normal. Lennox says aux heat that stays on more than about 30 minutes at a time means the heat pump can't handle the load, and suggests switching to emergency heat if you have it and calling a technician. A failed defrost board can also keep aux heat on far more than normal.

My heat pump won't shut off even when the thermostat is off. What's wrong?

Most likely a stuck (welded) contactor, the relay that powers the outdoor unit. Trane explains that a contactor welded closed keeps the unit running with constant power. Turn the unit off at its breaker or outdoor disconnect and call a technician; Trane treats it as an electrical repair for a professional.

Does a heat pump running all the time use a lot of electricity?

It uses more than one that cycles, but long, steady runs in cold weather are still how a heat pump is meant to work. The costly part is backup heat: if aux heat is on for long stretches, or the system runs nonstop in mild weather, your bills go up and something likely needs fixing.

Sources